resource if-type
Syntax
[ no ] resource if-type { atm-active-sub-if | atm-sub-if
| atm-vc | ip | ppp-link }
{ slot slot | system }
threshold { falling fallingValue | hold-down-time holdDownTime | rising
risingValue }
Release Information
Command introduced before JUNOSe Release
7.1.0.
Description
Specifies threshold values for specific interface
types on a slot or systemwide basis. The no version sets the threshold parameter to its default value (for rising,
90% of the maximum value of the resource; for falling, 1% of the maximum
value of the resource; for hold-down time, 300 seconds).
 |
Caution:
Do not specify a falling value larger
than the specified rising value; do not specify a rising value smaller
than the specified falling value.
|
Options
- atm-active-sub-if—Configures active ATM subinterfaces
- atm-sub-if—Configures both active and inactive ATM
subinterfaces
- atm-vc—Configures ATM virtual circuits
- ip—Configures IP interfaces
- ppp-link—Configures PPP link interfaces
-
slot—Number of the chassis
slot in the range 0–2 (ERX-310 model), 0–6 (ERX-7xx models),
0–13 (ERX-14xx models), 0–5 (E120 router), and 0-16 (E320
router)
- For ERX-7xx models, a number in the range 0–6; for
ERX-14xx models, a number in the range 0–13; for the ERX-310
router, a number in the range 1–2; for the E120 router, a number
in the range 0–5; for the E320 router, a number in the range
0–16
-
fallingValue—Falling threshold
for the resource, in the range 0–4294967295
-
holdDownTime—Hold-down time
for the resource, in the range 0–4294967295 seconds
-
risingValue—Rising threshold
for the resource, in the range 0–4294967295